              Vacuum deaerator-Vacuum deoxidizer-Wholesale manufacturer

              Vacuum D eaerator I. profile In the process of boiler feed water treatment deaeration is a key link. Oxygen is the main corrosive substance in feed water system and boiler. Oxygen in feed water should be removed quickly o therwise it wi

              Vacuum Deaerator

              Vacuum deaerator-Vacuum deoxidizer-Wholesale manufacturer-Price concession 

              I. profile

              In the process of boiler feed water treatment, deaeration is a key link. Oxygen is the main corrosive substance in feed water system and boiler. Oxygen in feed water should be removed quickly, otherwise, it will corrode the feed water system and components of the boiler.The corrosive product iron oxide will enter the boiler, deposit or attach to the tube wall and heating surface of the boiler, forming insoluble scales with poor heat transfer, and corrosion will cause pits on the inner wall of the pipeline and increase the resistance coefficient. When pipeline corrosion is serious, pipeline explosion may even occur. The state stipulates that all steam boilers with evaporation greater than or equal to 2 tons per hour and hot water boilers with water temperature greater than or equal to 95 degrees Celsius must be deoxidized. For many years, many boiler water treatment workers have been exploring both efficient and economical deoxidization methods, and vacuum deoxidization method is one of the best.

               Vacuum deaerator-Vacuum deoxidizer-Wholesale manufacturer-Price concession

              II. Operating principle

              In a closed container, if any gas exists on the water surface at the same time, the solubility of the gas is proportional to its own partial pressure, and the solubility of the gas is only related to its own partial pressure. Under certain pressure, with the increase of water temperature, the partial pressure of water vapor increases, while the partial pressure of air and oxygen is more and more small. The partial pressure of oxygen decreases to zero and the dissolved oxygen in water decreases to zero at 100 C. When the pressure on water surface is less than atmospheric pressure, the solubility of oxygen can also reach zero at lower water temperature. In this way, the oxygen molecules on the water surface are discharged or converted into other gases, so that the partial pressure of oxygen is zero, and the oxygen in the water is constantly escaping to achieve the effect of deoxidization. This deoxidization method is usually carried out at 30℃~60℃. It can realize deoxidization at low temperature (60℃ or ambient temperature). Satisfactory deoxidization effect can be obtained by vacuum method for thermal boilers and steam boilers with large fluctuation of load and poor thermal deoxidization effect. Compared with the thermal deoxidization technology, there are few restrictions on heating, the consumption of the boiler is reduced, and the vacuum deoxidizer can be arranged at a low position. The quality standard of the key equipment such as operation and management jet pump and pressurized pump are higher than those of thermal deoxidization. Low position layout also requires a certain height difference, and the operation and management requirements of key equipment such as jet pump, pressurized pump are also very high.

              Vacuum deaerator-Vacuum deoxidizer-Wholesale manufacturer-Price concession

               

              II. Advantage

              This product can be installed at a low position. It is suitable for deoxidation of steam boiler feed water, deoxidation of hot water heating boiler feed water and other systems requiring degassing of the system. The system has the following advantages:

              1. Not only the deoxidizing device can remove oxygen in water, but also can remove other gases such as carbon dioxide in water.

              2. No steam is consumed during deoxidization, and all boiler pressures are utilized.

              3. When there is no surplus steam in the hot water heating boiler, the supply water is deoxidized.

              4. Operation is stable, vacuum is high  and easy operation.

              5. The time from start-up to normal operation is fast. The deoxidization effect remains unchanged when the load changes in the range of 0-120%. 

              6. The deoxidized water will not increase the salt content and other impurities; it can be installed at a lowposition, and all small boiler rooms can be arranged on a single floor to save investment. 

              Vacuum deaerator-Vacuum deoxidizer-Wholesale manufacturer-Price concession

              VI .Model explain

               Vacuum deaerator-Vacuum deoxidizer-Wholesale manufacturer-Price concession

               

              V. Parts of the equipment

              1. Deaerator

              The vacuum deaerator operates under atmospheric pressure. The inlet temperature≤50 C, and the softened water is pumped to the inlet chamber of the deaeration head by the deaeration feed water pump. Water forms a rotating membrane under the inlet pressure. Because the water film has a large surface tension, it is not only conducive to the heat exchange between steam and water, but also conducive to the separation and escape of gas, so as to achieve the purpose of deoxidization. When the deoxidized water continues to flow down, it contacts with the grate and packing layer below, and forms water film again. The deep deoxidization improves the deoxidization effect.

              2. Deoxygenation tank

              The water in the deoxygenation tank is at its saturated pressure, and part of the boiling water evaporates, which is removed by the exhaust pipe together with the residual gas in the water, and then deep deoxygenation is carried out to complete the whole deoxygenation process. The fresh deoxygenated water is stored in the tank.

              Vacuum deaerator-Vacuum deoxidizer-Wholesale manufacturer-Price concession

               

              3. Vacuum Drainage Pump

              Because the water of deoxygenation tank pump is in vacuum state, in order to overcome negative pressure, prevent pump cavitation and maintain positive pressure before feeding pump, the deoxygenation tank must be placed at a place with more than 10 meters height in order to supply water with general feeding pump, which has some difficulties for layout of general small boiler room, so the special vacuum water diversion pump shall be installed at a low position.

              4. Vacuum pumping device

              The vacuum extraction device is the key component for that keep a certain degree of vacuum in the deaerator, draw the gases dissolved in water and with them are extracted together with the escaped unconsolidated steam in the vacuum deoxidization systemThe device is mainly composed of a water jet pump, a water jet air pump and a circulating water tank. Circulating water is supplied by tap water, and its water temperature should be 6-10℃ lower than that of softened water entering deaerator.

              Vacuum deaerator-Vacuum deoxidizer-Wholesale manufacturer-Price concession

              5. Deoxygenation tank water level automatic control device

              In order to ensure the safe operation of the deaerator under normal operating conditions, the deaerator water tank is equipped with an automatic water level control deviceThe device is mainly composed of a level gauge, a sensor and a solenoid valve. It can automatically alarm when the water level exceeds the maximum or minimum water level limit, and automatically open and close the deoxygenation feed pump and solenoid valve.

               

              V. Specification

               

              Model

              ZCY-4

              ZCY-6

              ZCY-10

              ZCY-20

              ZCY-35

              ZCY-50

              ZCY-100

              Rated output T/H

              4

              6

              10

              20

              35

              50

              100

              Working vacuum Kpa

              18.6-21.3

              18.6-21.3

              18.6-21.3

              5.3-80

              5.3-80

              5.3-80

              5.3-80

              Saturated

              water

              temperature 

              62.5

              62.5-57.5

              62.5-57.5

              42.5-37.5

              42.5-37.5

              42.5-37.5

              42.5-37.5

              Inlet water pressure MPa

              -0.2

              -0.2

              -0.2

              ~0.2

              ~0.2

              ~0.2

              ~0.2

              Oxygen content in effluent mg/L

              0.05-0.1

              0.05^).1

              0.05-0.1

              0.05-0.1

              0.05-0.1

              0.05-0.1

              0.05-0.1

              Water tank diameter mm

              900

              1200

              1400

              1600

              1800

              0)2000

              2800

              Diameter of deaerator  mm

              500

              600

              600

              800

              900

              1000

              1400

              Equipment weight kg

              -1150

              -1320

              -1800

              -2650

              -3900

              -5450

              -8760

               Note:The parameter in above tables are for reference only. The products can be customized and the relevant parameters should be provided.

              VII. Installation instruction

              1. Because the deaerator operates under negative pressure, the installation of pipes and valves must befree from leakage.

              2. The packing layer must be laid evenly and tightly, and the impurities in the equipment and pipeline should be flushed. 

              3. Horizontal deoxidizing water tank is supported on two saddle supports, one end of which is fixed support and other end is a long circular hole movable support convenient for thermal expansionthe foundation must be installed with a cushion plate, back two circles after tighten the bolts;

              4. Hydraulic pressure test must be carried out after deaerator installation. The test pressure is 0.25 Mpa. If the hydraulic test is qualified, the thermal insulation material f=80mm shall be used.

              Vacuum deaerator-Vacuum deoxidizer-Wholesale manufacturer-Price concessionVacuum deaerator-Vacuum deoxidizer-Wholesale manufacturer-Price concession


              97人人模人人爽人人喊电影
              <dfn id="uqoi2"><s id="uqoi2"></s></dfn>
              1. <th id="uqoi2"></th>
                <strike id="uqoi2"><video id="uqoi2"></video></strike>
                <strike id="uqoi2"><video id="uqoi2"></video></strike>

                    1. <th id="uqoi2"><video id="uqoi2"><span id="uqoi2"></span></video></th>
                        <strike id="uqoi2"><sup id="uqoi2"></sup></strike>